<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Inspiratory Flow Amplitude in Pediatric Acute Respiratory Distress Syndrome: Outcomes in a Single-Center Cohort, 2023–2024.

dc.contributor.authorCaviedes, Paola
dc.contributor.authorDíaz, Franco
dc.contributor.authorCruces, Pablo
dc.coverage.spatialEstados Unidos
dc.date.accessioned2026-11-25T19:31:14Z
dc.date.issued2026-11-01
dc.description.abstractOBJECTIVES: To evaluate whether inspiratory flow amplitude is independently associated with time to successful extubation in children with pediatric acute respiratory distress syndrome (PARDS) ventilated within lung-protective targets. DESIGN: Post hoc analysis of a pulmonary physiologic and clinical dataset collected in 2023–2024. SETTING: Single tertiary PICU. PATIENTS: Forty-eight mechanically ventilated children with early PARDS. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Standardized measurements of ventilatory parameters and respiratory mechanics collected within 2 hours of intubation during volume-controlled ventilation (VCV) with constant inspiratory flow and neuromuscular blockade. Inspiratory flow amplitude was the ventilator-reported mean inspiratory flow in VCV, a derived, setting-dependent metric. Median (interquartile range [IQR]) age was 11 months (IQR, 3–22 mo), and most patients had mild-to-moderate PARDS of viral etiology. Ventilation was delivered within protective limits for tidal volume, plateau pressure, positive end-expiratory pressure, driving pressure, and inspiratory time. The median inspiratory flow amplitude was 0.9 L/min/kg (IQR, 0.6–1.1 L/min/kg). The primary outcome was time to successful extubation. In multivariable Cox proportional hazards regression adjusted for age, oxygenation index, tidal volume, respiratory rate, and resistive airway pressure (peak inspiratory pressure minus plateau pressure), higher inspiratory flow amplitude was independently associated with a lower hazard of successful extubation over time (hazard ratio, 0.20; 95% CI, 0.06–0.75; p = 0.017). Multicollinearity assessment showed no clinically relevant collinearity among covariates. Sensitivity analyses confirmed the robustness and directional consistency of this association. In complementary linear regression, each 0.1 L/min/kg increase in inspiratory flow amplitude was associated with 3.5 hours (95% CI, 0.7–6.3 hr) of prolonged mechanical ventilation. CONCLUSIONS: Among children with early PARDS ventilated within lung-protective limits, higher inspiratory flow amplitude was independently associated with delayed extubation. Inspiratory flow amplitude may represent an integrative marker of dynamic ventilatory load not fully captured by conventional static parameters. These findings are observational and hypothesis-generating and support further investigation of inspiratory flow in PARDS.
dc.identifier.citationPediatric Critical Care Medicine, Vol. 27, N° 11 (2026) p. 1477-1485
dc.identifier.doihttps://doi.org/10.1097/PCC.0000000000004054
dc.identifier.issn1947-3893
dc.identifier.orcid0000-0003-4763-074X
dc.identifier.urihttps://hdl.handle.net/20.500.12254/7873
dc.language.isoen
dc.publisherWolters Kluwer Health
dc.relation.ispartofPediatric Critical Care Medicine
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Chile (CC BY-NC-SA 3.0 CL)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/cl/
dc.subjectinspiratory flow
dc.subjectmechanical ventilation
dc.subjectpediatric acute respiratory distress syndrome
dc.subjectpediatric intensive care unit
dc.titleInspiratory Flow Amplitude in Pediatric Acute Respiratory Distress Syndrome: Outcomes in a Single-Center Cohort, 2023–2024.
dc.typeArtículo
oaire.citation.endPage1485
oaire.citation.issue11
oaire.citation.startPage1477
oaire.citation.volume27

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
8_inspiratory-flow-amplitude-in-pediatric-acute-respiratory.pdf
Tamaño:
1,07 MB
Formato:
Adobe Portable Document Format