<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Pressure Points: A Scoping Review of Intracranial Pressure and Mean Arterial Pressure Measurement and Reporting Practices in Neurocritical Care

dc.contributor.authorEltit, Marisol
dc.contributor.authorGonzález, Alejandra
dc.contributor.authorGiglio, Andrés
dc.contributor.authorPino, Monserrat
dc.contributor.authorFerre, Andrés
dc.contributor.authorReccius, Andrés
dc.coverage.spatialEstados Unidos
dc.date.accessioned2026-11-24T19:48:35Z
dc.date.issued2026-10-09
dc.description.abstractCerebral perfusion pressure (CPP) is a cornerstone of neurocritical care, but the literature shows substantial heterogeneity in how its components, intracranial pressure (ICP) and mean arterial pressure (MAP), are reported. We conducted a scoping review following the Joanna Briggs Institute methodology and PRISMA-ScR to map this variability. Structured searches in PubMed and Scopus (January 1997 to May 2026) identified 350 eligible original clinical studies. For each study, we extracted whether the ICP measurement method, ICP device, ICP zero reference, MAP measurement method, and arterial line zero reference were reported. Reporting completeness was analyzed overall and stratified by guideline era and primary diagnosis, using the χ2 tests, odds ratios with 95% CI, and the Cochran-Armitage test for trend. The ICP measurement method was reported in 84.0% of studies, and the ICP zero reference in 14.6%; the MAP method in 66.9%, and the arterial line zero reference in 28.6%. Only 6.6% of studies reported all 5 domains. After publication of the Brain Trauma Foundation fourth Edition, reporting improved across most domains (ICP method, 79.0% vs. 96.1%, P < 0.001; arterial line zero reference, 20.2% vs. 49.0%, P < 0.001) and the composite reporting score rose from 2.37 to 3.06 (P < 0.001). ICP zero-reference reporting was similar between eras (16.5% vs. 9.8%, P = 0.105) while showing a significant declining trend across the study period (Cochran-Armitage Z = −2.52, P = 0.012). Traumatic brain injury and hemorrhagic conditions had the lowest ICP zero reference reporting (8.8% and 9.3%; OR = 0.35 for TBI vs. non-TBI, 95% CI: 0.19-0.65). Improvements in reporting have not reached the level needed to determine whether CPP values are comparable across studies. We propose an 11-item Minimum Reporting Set for CPP-related studies.
dc.identifier.citationJournal of Neurosurgical Anesthesiology (2026)
dc.identifier.doihttps://doi.org/10.1097/ANA.0000000000001172
dc.identifier.issn0898-4921
dc.identifier.issn1537-1921
dc.identifier.orcidhttps://orcid.org/0000-0002-0533-4531
dc.identifier.urihttps://hdl.handle.net/20.500.12254/7866
dc.language.isoen
dc.publisherWolters Kluwer Health
dc.relation.ispartofJournal of Neurosurgical Anesthesiology
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Chile (CC BY-NC-SA 3.0 CL)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/cl/
dc.subjectarterial pressure
dc.subjectcerebrovascular circulation
dc.subjectcritical care
dc.subjectintracranial pressure
dc.subjectresearch report
dc.titlePressure Points: A Scoping Review of Intracranial Pressure and Mean Arterial Pressure Measurement and Reporting Practices in Neurocritical Care
dc.typeArtículo

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
ana.0000000000001172.pdf
Tamaño:
2,24 MB
Formato:
Adobe Portable Document Format