Comparación de equipos acelerométricos en la captura de características invariantes en dos subpruebas del Action Research Arm Test en sujetos sanos

dc.contributor.advisorHerrero Silva, Joaquín Alfonso prof. guíaes
dc.contributor.authorArias Alcaide, Felipe Alberto
dc.contributor.authorRiquelme Torres, Bárbara Nicole
dc.coverage.spatialSantiago, Chilees
dc.date.accessioned2023-06-07T13:26:49Z
dc.date.available2023-06-07T13:26:49Z
dc.date.issued2021
dc.descriptionTesis (Licenciado en Kinesiología)--Universidad Finis Terrae, 2021es
dc.description.abstractAntecedentes: El Action Research Arm Test (ARAT) es un instrumento validado para la medición de funcionalidad de las actividades de la extremidad superior (ES) patologías neurológicas, evaluando la manipulación, alcance y agarre, orientadas a movimientos funcionales. La acelerometría es una medición instrumentada del movimiento, útil para monitorear objetivamente actividades de la ES. En este sentido, la posibilidad de mediciones funcionales instrumentadas cobra relevancia ante la posibilidad de obtener variables del control del movimiento difíciles de objetivar. Así, dispositivos de alta accesibilidad y bajo costo pueden ser claves para su aplicación en la clínica, por lo que su validación en parámetros entregados es fundamental. Objetivo: Comparar la similitud entre sensores de aceleración en la captación del movimiento en dos subpruebas del Action Research Arm Test en sujetos sanos. Hipótesis: La medición de MetaMotionR y Sensor Kinetics Pro presentan similitudes en los patrones acelerométricos ante la aplicación de dos subpruebas del Action Research Arm Test. Metodología: Se registraron 30 sujetos jóvenes de la Universidad Finis Terrae. Se aplicaron dos subpruebas del ARAT (P1) y (P2) con ambos acelerómetros de forma simultánea. Resultados: De acuerdo al análisis realizado, tanto para P1 y P2, se obtuvieron similitudes en sus patrones acelerométricos, según la medición de sus peak, demostrando que no hay diferencias significativas entre acelerómetros.es
dc.description.abstractBackground: The Action Research Arm Test (ARAT) is a validated instrument for the measurement of functionality of the activities of the upper limb (ES) neurological pathologies, evaluating manipulation, reach and grip, oriented to functional movements. Accelerometry is an instrumented measurement of movement, useful for objectively monitoring SE activities. In this sense, the possibility of instrumented functional measurements becomes relevant given the possibility of obtaining variables of the control of movement that are difficult to objectify. Thus, devices with high accessibility and low cost can be key for their application in the clinic, so their validation in delivered parameters is essential. Objective: To compare the similarity between acceleration sensors in capturing movement in 2 subtests of the Action Research Arm Test in healthy subjects. Hypothesis: The measurement of MetaMotionR and Sensor Kinetics Pro show similarities in the accelerometric patterns after the application of two subtests of the Action Research Arm Test. Methodology: 30 young subjects from Universidad Finis Terrae were registered. Two ARAT subtests (P1) and (P2) were applied with both accelerometers simultaneously. Results: According to the analysis carried out, both for P1 and P2, similarities were obtained in their accelerometric patterns, according to the measurement of their peaks, showing that there are no significant differences between accelerometers.en
dc.identifier.urihttp://hdl.handle.net/20.500.12254/3281
dc.language.isoeses
dc.publisherUniversidad Finis Terrae (Chile) Facultad de Medicinaes
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Chile (CC BY-NC-SA 3.0 CL)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/cl/
dc.subjectTRASTORNOS DEL MOVIMIENTO--PACIENTES--REHABILITACIONes
dc.subjectMOVIMIENTOes
dc.subjectACELEROMETRÍAes
dc.subjectTESIS DIGITALes
dc.subject.otherAcelerometríaes
dc.subject.otherARATes
dc.subject.otherControl del movimientoes
dc.subject.otherSensor de movimientoes
dc.subject.otherUnidades de medición inerciales
dc.subject.otherAccelerometryes
dc.subject.otherMotion Controles
dc.subject.otherMotion Sensores
dc.subject.otherInertial Measurement Unitses
dc.titleComparación de equipos acelerométricos en la captura de características invariantes en dos subpruebas del Action Research Arm Test en sujetos sanoses
dc.typeTesises
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Arias_Riquelme_2021.pdf
Size:
1.43 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
638 B
Format:
Item-specific license agreed upon to submission
Description:
Collections